  • Oil Test Set

    NEO TELE-TRONIX PVT. LTD

    We are the most reliable manufacturer and exporter of Oil Test Set that is ideal for testing of Breakdown / Withstand Test of Transformer and Circuit Breaker Oil. This test set is manufactured using premium quality raw material under the supervision of versed professionals. Moreover, the offered test set is checked by our quality inspectors on various parameters to ensure its flawlessness at clients' end. Our valuable clients can avail this Oil Test Set from us at competitive prices.

  • Ground-Fault Location Products for Ungrounded Systems

    Bender Inc.

    When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.

  • Low Resistance Ohmmeters

    Megger Group Ltd.

    Some times know as Ducter testers, these are highly accurate, easy to operate instruments that measure resistance with resolution as fine as 0.1 micro-ohm. Digital micro-ohmeters and DLROs measure contact resistance of switch and circuit breakers, aircraft frame bonds, and rail and pipeline bonds just to name a few of the applications. Megger has models available for testing using test currents from 0.5 mA to 200 amps covering a multitude of applications that require precise low-resistance measurements.

  • Primary Injection Test Systems

    Megger Group Ltd.

    Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.

  • 3 Wire (Digital) Earth Resistance Tester

    1120 ER - Standard Electric Works Co., Ltd

    ● Waterproof: IP54● Capable of measuring earth resistance and earth voltage● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test● The test leads are supplied as standard accessories for simplified two-wire measuring system● 0Ω adjustment● Battery operated● Data hold function● Low battery indication

  • Primary Injection Test Systems

    Megger Group Ltd.

    Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.

  • Contact Resistance Meter

    CRM 200B+ - Scope T&M Pvt, Ltd.

    CRM directly measures micro-ohm values at 200A DC under live EHV switchyard conditions quickly & accurately. It is specially designed to reliably measure micro-ohm contact resistances of Circuit Breakers, Isolators, Busbar joints, earth switch joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards up-to 765 kV. SCOPE’s ability to make electronics work in such environment enables CRM to measure mili-volts signal in the presence of kilo-volts noise.

  • Transformer Rectifier Assemblies

    Carl E. Holmes Company

    Transformer rectifier assemblies are very useful in OEM applications when unregulated DC output is required. Input power can be single-phase or three phases. With single-phase input power, the output ripple is 50%. With three-phase input power, the output ripple is 5%. A 5% output ripple is a clear advantage. Hence, transformer rectifier assemblies with three-phase input power are more popular. Circuit breakers, fuses, voltmeters, and ammeters can be added per customer requirements. The assemblies can be an open frame or inside an indoor enclosure.

  • Relay Test Equipment

    Vanguard Instruments Company, Inc.

    The VIC Model PCI-600 is a programmable, high-current source that is designed specifically for utility-substation applications. This alternating current(ac) test device is used primarily for injection testing of protective relays. This same device can also be used for testing thermal, magnetic and solid-state motor-protection relays and molded-case circuit breakers. The PCI-600 is versatile and can also be used in many other applications that require a high-current source.

  • 3 Wire (Digital) Earth Resistance Tester

    2720 ER - Standard Electric Works Co., Ltd

    ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.

  • 3 Wire (Digital) Earth Resistance Tester

    1820 ER - Standard Electric Works Co., Ltd

    ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.

  • 3 Wire (Digital) Earth Resistance Tester

    4120 ER - Standard Electric Works Co., Ltd

    ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.

  • Multiple Channel Burn In Power Supply

    MCPS - Test Electronics

    The most important features of this burn in power supply is its ability to hold a constant output for each channel even in the event that a unit under test on one channel may short and fail. Since each channel has it''s own transformer, no glitches or voltage spikes can get into any of the other channels. This image shows the results as the second channel from the left is shorted with a small wire and the circuit breaker pops out. Used for burn-in testing and other timed testing where power isolation is required. Very basic simple circuit, see schematic below. Cleans and frees up benchtops, burn in racks and work space clutter. Available in benchtop or rackmount.

  • Air Core Test Lab Reactors

    Hilkar

    Test Laboratory Reactors are designed for high voltage and high power test laboratories. They are designed to withstand the most extreme electrical service conditions during test periods. Design techniques are implemented in accordance with the most demanding service conditions. These reactors are used for various purposes in test laboratories such as current limiting and synthetic testing of circuit breakers, capacitor testing, artificial line simulation etc.

  • Primary Current Injection Testers

    Hilkar

    Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.